Files
MatikandClaude Opus 5.5 9bcca5d9e3 Etap 3: broker EMQX z TLS i ACL, symulator czujnika ciśnienia, instrukcja
- docker-compose: EMQX 5.8.6 (1883/8883/18083), symulator (FastAPI, MQTT 5), sniffer tcpdump
- emqx.conf, acl.conf: uwierzytelnianie, autoryzacja (default deny), TLS
- hasła wyłącznie w pliku .env (poza repozytorium), konta tworzone przy starcie brokera
- skrypty: generowanie certyfikatów, podgląd w Wiresharku, klient SCADA
- INSTRUKCJA.md: wykonanie zadań i zbieranie dowodów do sprawozdania
- screeny/: zrzuty ekranu do sprawozdania

Co-Authored-By: Claude Opus 5.5 <[email protected]>
2026-11-23 19:26:25 +01:00

267 lines
8.2 KiB
Python

"""Symulator czujnika ciśnienia MQTT z panelem WWW (FastAPI)."""
import json
import os
import socket
import threading
import time
from pathlib import Path
from fastapi import FastAPI
from fastapi.responses import FileResponse, JSONResponse
from fastapi.staticfiles import StaticFiles
from pydantic import BaseModel, Field
from app.mqtt_manager import EventLog, MqttManager
from app.sensor import PressureSensor
STATIC = Path(__file__).resolve().parent.parent / "static"
def env(name: str, default: str) -> str:
return os.getenv(name, default)
DEFAULTS = {
"host": env("MQTT_HOST", "emqx"),
"plain_port": int(env("MQTT_PLAIN_PORT", "1883")),
"tls_port": int(env("MQTT_TLS_PORT", "8883")),
"tls": env("MQTT_TLS", "false").lower() in ("1", "true", "yes"),
"tls_version": env("MQTT_TLS_VERSION", "1.2"),
"verify": True,
"ca_file": env("MQTT_CA_FILE", "/certs/ca.crt"),
"client_id": env("MQTT_CLIENT_ID", f"pt101-{socket.gethostname()[:6]}"),
"username": env("MQTT_USERNAME", "czujnik_cisnienia"),
"password": env("MQTT_PASSWORD", ""),
"scada_password": env("SCADA_PASSWORD", ""),
"sensor_id": env("SENSOR_ID", "PT-101"),
"telemetry_topic": env("TOPIC_TELEMETRY", "zaklad/hala1/cisnienie/telemetria"),
"status_topic": env("TOPIC_STATUS", "zaklad/hala1/cisnienie/status"),
"command_topic": env("TOPIC_COMMANDS", "zaklad/hala1/cisnienie/komendy"),
"interval": float(env("PUBLISH_INTERVAL", "2")),
"qos": int(env("PUBLISH_QOS", "1")),
}
log = EventLog()
sensor = PressureSensor(DEFAULTS["sensor_id"])
history: list[dict] = []
history_lock = threading.Lock()
class Publisher:
"""Wątek cyklicznie wysyłający pomiary."""
def __init__(self):
self.running = False
self.interval = DEFAULTS["interval"]
self.qos = DEFAULTS["qos"]
self.topic = DEFAULTS["telemetry_topic"]
self._wake = threading.Event()
self._last = time.monotonic()
threading.Thread(target=self._loop, daemon=True, name="publisher").start()
def publish_once(self) -> dict:
now = time.monotonic()
reading = sensor.read(now - self._last)
self._last = now
with history_lock:
history.append({"t": time.time(), "p": reading["pressure"], "s": reading["status"]})
del history[:-120]
return mqtt_mgr.publish(self.topic, reading, qos=self.qos, kind="telemetry")
def _loop(self):
while True:
self._wake.wait(self.interval)
self._wake.clear()
if self.running:
res = self.publish_once()
if not res["ok"] and mqtt_mgr.state == "disconnected":
self.running = False
log.add("warn", "Zatrzymano wysyłanie pomiarów - brak połączenia")
def poke(self):
self._wake.set()
def handle_command(topic: str, text: str) -> None:
"""Komendy od SCADA, np. {"cmd":"set_interval","value":1} lub {"cmd":"set_setpoint","value":5.5}."""
if topic != mqtt_mgr.settings.get("command_topic"):
return
try:
cmd = json.loads(text)
except json.JSONDecodeError:
log.add("warn", "Komenda nie jest poprawnym JSON-em - zignorowano")
return
name, value = cmd.get("cmd"), cmd.get("value")
if name == "set_interval" and isinstance(value, (int, float)) and 0.2 <= value <= 3600:
publisher.interval = float(value)
publisher.poke()
log.add("ok", f"Komenda SCADA: zmieniono interwał na {value} s")
elif name == "set_setpoint" and isinstance(value, (int, float)) and 0 <= value <= 50:
sensor.setpoint = float(value)
log.add("ok", f"Komenda SCADA: wartość zadana = {value} bar")
elif name == "start":
publisher.running = True
publisher.poke()
log.add("ok", "Komenda SCADA: start pomiarów")
elif name == "stop":
publisher.running = False
log.add("ok", "Komenda SCADA: stop pomiarów")
else:
log.add("warn", f"Nieznana komenda: {text}")
mqtt_mgr = MqttManager(log, on_message=handle_command)
publisher = Publisher()
app = FastAPI(title="Symulator czujnika ciśnienia MQTT")
app.mount("/static", StaticFiles(directory=STATIC), name="static")
# ---------------------------------------------------------------- modele żądań
class ConnectReq(BaseModel):
host: str = Field(min_length=1, max_length=253)
port: int = Field(ge=1, le=65535)
tls: bool = False
tls_version: str = "1.2"
verify: bool = True
ca_file: str = "/certs/ca.crt"
client_id: str = Field(min_length=1, max_length=64)
username: str = ""
password: str = ""
sensor_id: str = "PT-101"
status_topic: str = ""
command_topic: str = ""
class SensorReq(BaseModel):
topic: str | None = None
interval: float | None = Field(default=None, ge=0.2, le=3600)
qos: int | None = Field(default=None, ge=0, le=2)
setpoint: float | None = Field(default=None, ge=0, le=50)
sensor_id: str | None = None
class PublishReq(BaseModel):
topic: str = Field(min_length=1)
payload: str = ""
qos: int = Field(default=1, ge=0, le=2)
retain: bool = False
class SubscribeReq(BaseModel):
topic: str = Field(min_length=1)
qos: int = Field(default=1, ge=0, le=2)
# ---------------------------------------------------------------- endpointy
@app.get("/")
def index():
return FileResponse(STATIC / "index.html")
@app.get("/api/defaults")
def defaults():
return DEFAULTS
@app.get("/api/state")
def state(after: int = 0):
with history_lock:
hist = list(history)
return {
"mqtt": mqtt_mgr.status(),
"sensor": {
"running": publisher.running,
"interval": publisher.interval,
"qos": publisher.qos,
"topic": publisher.topic,
"sensor_id": sensor.sensor_id,
"setpoint": sensor.setpoint,
"alarm_low": sensor.alarm_low,
"alarm_high": sensor.alarm_high,
"last": hist[-1] if hist else None,
},
"history": hist,
"events": log.since(after),
}
@app.post("/api/connect")
def connect(req: ConnectReq):
publisher.running = False
sensor.sensor_id = req.sensor_id or sensor.sensor_id
res = mqtt_mgr.connect(req.model_dump())
return JSONResponse(res, status_code=200 if res["ok"] else 400)
@app.post("/api/disconnect")
def disconnect():
publisher.running = False
mqtt_mgr.disconnect()
return {"ok": True}
@app.post("/api/sensor/config")
def sensor_config(req: SensorReq):
if req.topic is not None:
publisher.topic = req.topic.strip()
if req.interval is not None:
publisher.interval = req.interval
publisher.poke()
if req.qos is not None:
publisher.qos = req.qos
if req.setpoint is not None:
sensor.setpoint = req.setpoint
if req.sensor_id:
sensor.sensor_id = req.sensor_id
return {"ok": True}
@app.post("/api/sensor/start")
def sensor_start():
if mqtt_mgr.state != "connected":
return JSONResponse({"ok": False, "error": "Najpierw połącz się z brokerem"}, status_code=400)
publisher.running = True
publisher.poke()
log.add("info", f"Start cyklicznego wysyłania co {publisher.interval:g} s na '{publisher.topic}'")
return {"ok": True}
@app.post("/api/sensor/stop")
def sensor_stop():
if publisher.running:
log.add("info", "Zatrzymano cykliczne wysyłanie")
publisher.running = False
return {"ok": True}
@app.post("/api/sensor/once")
def sensor_once():
res = publisher.publish_once()
return JSONResponse(res, status_code=200 if res["ok"] else 400)
@app.post("/api/sensor/spike")
def sensor_spike():
sensor.spike()
log.add("info", "Wymuszono skok ciśnienia (symulacja zakłócenia procesu)")
return {"ok": True}
@app.post("/api/publish")
def publish(req: PublishReq):
res = mqtt_mgr.publish(req.topic.strip(), req.payload, qos=req.qos, retain=req.retain)
return JSONResponse(res, status_code=200 if res["ok"] else 400)
@app.post("/api/subscribe")
def subscribe(req: SubscribeReq):
res = mqtt_mgr.subscribe(req.topic.strip(), qos=req.qos)
return JSONResponse(res, status_code=200 if res["ok"] else 400)
@app.post("/api/log/clear")
def clear_log():
log.clear()
return {"ok": True}